Ametek PLA-PLW Programming Manual Manual de usuario Pagina 59

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 74
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 58
55
return the presently programmed voltage levels. After a trigger or ABORt,
VOLTage:TRIG? returns the same value as VOLTage? .
VOLTage? MAX, VOLTage? MIN, V OLTage:TRIG? MAX and
VOLTage:TRIG? MIN return the maximum and minimum programmable
LEVel and TLEVel values.
[SOURce:]VOLTage:[TRANsient:]DUTY
This command sets the duty cycle of each of the transients when the generator is in CONTinuous
mode.
Command Syntax VOLTage:DUTY <NR1>
VOLTage:TRANsient:DUTY <NR1>
Parameters Duty cycle value, 1 - 100
Unit Percentage
Query Syntax VOLTage:DUTY?
VOLTage:DUTY? MIN VOLTage:DUTY? MA X
VOLTage:TRANsient:DUTY?
VOLTage:TRANsient:DUTY? MIN
VOLTage:TRANsient:DUTY? MAX
Returned Parameters <NR1> an integer representing duty cycle value
[SOURce:]VOLTage:[TRANsient:]FREQuency
This command sets the frequency of the transients when the generator is in CONTinuous mode.
Command Syntax VOLTage:FREQuency <NRf+>
VOLTage:TRANsient:FREQuency <NRf+>
Parameters Frequency value, refer to model specifications | MIN | MAX
Unit Hertz
Query Syntax VOLTage:FREQuency?
VOLTage: FREQuency? MIN VOLTage:FREQuency? MAX
VOLTage:TRANsient:FREQuency?
VOLTage:TRANsient:FREQuency? MIN
VOLTage:TRANsient:FREQuency? MAX
Returned Parameters <NRf+> f req
uency v
alue in Hz
[SOURce:]VOLTage:PROTection[:LEVel]
[SOURce:]VOLTage:PROTection:OVER[:LEVel]
[SOURce:]VOLTage:PROTection:DELay
[SOURce:]VOLTage:PROTection:OVER:DELay
[SOURce:]VOLTage:PROTection:UNDer:DELay
[SOURce:]VOLTage:PROTection:STATe
[SOURce:]VOLTage:PROTection:UNDer[:LEVel]
[SOURce:]VOLTage:PROTection:UNDer:STATe
Channel-Specific Voltage Limiting Command/Query. This command sets the over-voltage
protection limit or the under-voltage protect limit to the input voltage that the electronic load will sink.
When the input voltage reaches the protection limit for the specified delay period, the input of the
electronic load is shut off and draws no voltage.
The INPut:PROTection:CLEar command (or front panel key) re-enables the input voltage. The trigger
activated voltage functions (VOLTage[:LEV]:TRIG and VOLTage:TLEV) a utomatically keep tra ck of