28
MEASUREMENT COMMANDS
MEASure:CURRent[:DC]?
MEASure:POWer[:DC]?
MEASure:RESistance[:DC]?
MEASure:VOLTage[:DC]?
MEASure:VOLTage:INPut?
This function consists of queries that return the current, power, resistance ,and voltage at the
input of the electronic load.
Query Syntax
MEASure:CURRent? electronic load input current
MEASure:POWer? Computed electronic load input power
MEASure:RESistance? Computed electronic load input resiatance
MEASure:VOLTage? electronic load input voltage
MEASure:VOLT:INPut? electronic load input voltage at input end
Returned parameters <NRf+> Value representing amperes, watts, ohm, or volts
MEASure:DELay
This command is to sets or queries the delay time to obtain read back value for “MEAS:CURR?”,
“MEAS:POW?”, “MEAS:RES?” and “MEAS:VOLT?” queries.
Command Syntax MEASure:DELay <NR1>
Parameters 0 t0 2000 | MIN | MAX
Unit milli-second
Query Syntax MEASure:DELay?
MEASure:DELay? MIN MEASure:DELay? MAX
Returned Parameters <NR1> delay time in ms
MEASure:SENSe
This command sets or queries the measurement sense (Local / Remote ).
Note: When input voltage is greater than 30 V, this command will cause an execution error.
Command Syntax MEASure:SENSe <bool>
Parameters 0 | 1 | LOCal(0) | REMote(1)
Query Syntax MEASure:SENSe?
Returned Parameters <bool> 0=LOCal
1=REMote