Ametek ReFlex Programming Manual Manual de usuario Pagina 78

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 134
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 77
ReFlex Power™ Programming Manual DC Module Remote Programming
74 M380056-03 Rev M
ID LE S TA T E
IN IT IA TE D ST A T E
D W E LLIN G S T A T E
O U TP U T C O N D IT IO N
C H AN G E
D W E LLIN G S T A T E
LIS T
D O N E ?
A B O R T
R E S E T
Y E S
TR IG G E R E V E NT
D W EL L C O M P L E TE
D W EL L C O M P L E TE
A R M IN G EV E NT
TR IG G E R W A IT S TA T E
N O
Figure 3-8. List Mode Logic
M
ODULE
O
PERATION IN
LIST
C
REATION
M
ODE
When a LIST is being created in a module, the module is placed in a special
mode. This mode inhibits actual relay operation, to minimize any chance of
energizing an external load. The output relays are inhibited from closing on
STATE ON commands.
RAMP commands go from start point to endpoint with no delay. Trigger
output, WAIT’s and DWELL’s are not executed. Setpoint commands are
executed. All query commands except actual relay states and MEAS:CURR
are fully functional.
Vista de pagina 77
1 2 ... 73 74 75 76 77 78 79 80 81 82 83 ... 133 134

Comentarios a estos manuales

Sin comentarios