ReFlex Power™ Programming Manual Load Module Remote Programming
112 M380056-03 Rev L
R
EADBACK
F
UNCTIONS
• Actual measured voltage, power and current
• Voltage, current and resistance settings
• Soft voltage, power and current limits
• Status and Accumulated Status registers
• Programming error codes
• Fault codes
• Manufacturer, power supply model, serial number, and firmware
version identification
5.3
POWER-ON CONDITIONS
Table 5-1 presents the power-on conditions for the Active Loads.
Table 5-1. Load Power-on Conditions
Condition Default
Current
0 Amps (initial power–on current). Also see
CAL<n>:INIT:CURR
Soft Voltage Limit Model maximum voltage
Soft Current Limit Model maximum current
OVP Trip Voltage
Model maximum voltage +7% (initial power–on OVP).
See
CAL<n>:INIT:VOLT:PROT
Input OFF, relays open
Grouped No Modules Grouped (example paralleled)
Soft Power Limit Model power limit