DC Module Remote Programming ReFlex Power™ Programming Manual
M380056-03 Rev L 63
3.9.2 SOURCE
SCPI
C
OMMAND
R
EFERENCE
SOURce<n>
Source subsystem. Module ‘n’.
:CURRent <NRf>
Sets the output current in amps.
:CURRent?
Query the set output current in amps.
:LIMit <NRf>
Sets an upper soft limit on the programmed output current for
the supply.
:LIMit?
Query an upper soft limit on the programmed output current
for the supply.
:PROTection <NRf>
Sets the overcurrent protection trip point in amps
:PROTection?
Query the overcurrent protection trip point in amps
:TRACKing <bool>
Set the over current protection to tracking. 1 means turn on
the tracking supervisory and 0 means turn off the tracking
supervisory
:TRACKing?
Query the tracking supervisory status.
:MODE?
Query, 1 is constant current mode, 0 is voltage mode. See
OUTP[n]:PROT:FOLD command.
:RAMP
See Table 3-9. For Software Ramps
:TRIGger
See Table 3-8. For Software Setpoints
:VOLTage <NRf>
Sets the output voltage of the supply in volts. *See note at end
of this table.
:VOLTage?
Query the set point of the output voltage of the supply in volts.
:LIMit <NRf>
Sets the upper soft limit on the programmed output voltage.
:LIMit?
Query an upper soft limit on the programmed output voltage.
:PROTection <NRf>
Sets the overvoltage protection trip point in volts.
:PROTection?
Query the set point of the overvoltage protection trip point in
volts.
:TRACKing <bool>
Set the over voltage protection mode to tracking. 1 equals on,
and 0 turns off the tracking supervisory.
:TRACKing?
Query the tracking supervisory status.
:ENABle <bool>
Disable OVP when OFF, Save current setting, and set OVP to
factory maximum value. When ON, restore the saved OVP
setting.
:ENABle?
Query if OVP is Enabled or Disabled.
:RAMP
See Table 3-9. For Software Ramps
:TRIGger
See Table 3-8. For Software Setpoints
:UNDERVOLTage
:PROTection <NRf>
Sets the undervoltage protection trip point in volts.
:PROTection?
Query the set point of the undervoltage protection trip point in
volts.
:TRACKing <bool>
Set under voltage protection tracking. 1 = On, 0= Off.
:TRACKing?
Query the tracking supervisory status.
:TRIPped?
Returns 1 if the supply has an undervoltage fault
*Note: Set and Query the state of the polarity relay using the OUTPut<n>:POLarity
command.