ReFlex Power™ Programming Manual DC Module Remote Programming
60 M380056-03 Rev M
3.8
OUTPUT SCPI COMMANDS
3.8.1 OUTPUT
SCPI
C
OMMAND
S
UMMARY
OUTPut[n]
:ISOLation <bool>
:DEFault <bool>
:DEFault?
:ISOLation?
:POLarity <NORM/0/OFF|INV/1/ON>
:POLarity?
:PROTection
:DELAY <NRf>
:DELAY?
:FOLD <NRi>
:FOLD?
:SENSe <bool>
:DEFault <bool>
:DEFault?
:SENse?
:STATe <bool>
:STATe?
:TRIPped?
:MODFault <bool>
:MODFault?
:CLEar <bool>
:CLEar?
:DPDelay
:TIMER <NRf>
:TIMER?
3.8.2 OUTPUT
SCPI
C
OMMAND
R
EFERENCE
OUTPut<n>
Output subsystem. Module ‘n’.
:ISOLation <bool>
Turns 1/ON or 0/OFF, the output isolation relay. The output
voltage must be set to zero prior to issuing this command. The
ISOL relay can’t be opened if Sense relay is closed.
:ISOLation?
Query the state of the ISOLation relay. 0 = open, 1 = closed.
:
DEFault <bool>
Sets DEFault state of ISOL Relay, POR default state is ON. The
ISOL/SENSe relays will be automatically sequenced during the
STATE command.
:
DEFault?
Query DEFault state of Isolation relay
:POLarity
<NORM/0/OFF | INV/1/ON>
Changes the state of the polarity relay. This command requires
that the isolation/sense relays be opened beforehand. If the
isolation relay is closed when this command is attempted, the
state of the polarity relay will not change, and an error message