Vista de pagina 123
ReFlex Power™ Programming Manual Load Module Remote Programming
120 M380056-03 Rev L
Command
Description
:DELAY <NRi>
Set the power protection delay time in mSec.
The range for the delay is 1 to 100mSec.
Default delay time is 1mSec
Delay time takes effect as soon as the command is sent.
The Reset command sets the delay time to the default value.
:DELAY?
Returns the value of the Power protection delay time.
5.10
STATUS SCPI COMMANDS
5.10.1
STATUS
SCPI
C
OMMAND
S
UMMARY
STATus<n>
:MODule
:ENABles <0+NR1>
:ENABles?
:FAULts?
5.10.2
STATUS
SCPI
C
OMMAND
R
EFERENCE
Command
Description
STATus<n>
STATUS subset of SCPI commands.
:MODule
:ENABles<0+NR1>
Enable the supervisory see Table 5-2.
:ENABles?
Query the enabled supervisories
:FAULts?
Query the module faults