BPS / MX / RS Series SCPI Programming Manual AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA 69
MEASure:POWer:AC:PFACtor?
FETCh:POWer[:AC]:PFACtor?
Phase Selectable
This query returns the output power factor. The power factor is computed as:
power factor = real power / apparent power
Query Syntax MEASure[:SCALar]:POWer[:AC]:PFACtor?
Parameters None
Examples MEAS:POW:PFAC?
Returned Parameters <NR2>
Related Commands INST:NSEL
MEASure:POWer:DC?
FETCh:POWer:DC?
Phase Selectable
This query returns the DC component of the power being sourced at the output terminals in
kilo watts (KW). The query should be used only when the voltage mode is set for DC or an
error message will be generated.
Query Syntax MEASure[:SCALar]:POWer:DC?
Parameters None
Examples MEAS:POW?
Returned Parameters <NR2>
Related Commands INST:NSEL