M362299-01 Rev B www.programmablepower.com DLM 600W Series Power Supplies M51A Option Isolated Analog Programming Manual
Contents DLM 600W Series LIST OF TABLES Table 2–1. INTFC SETUP Switch...
SECTION 1 M51A OPTION OVERVIEW 1.1 Introduction This addendum is to be used in conjunction with the DLM 600W Series Power Supplies Operation Manual,
M51A Option Overview DLM 600W Series 1.3 Specifications 1.3.1 Electrical Specifications Remote Voltage Programming Accuracy, 0-5/10V Inputs: Outp
SECTION 2 ISOLATED REMOTE ANALOG INTERFACE OPERATION 2.1 INTFC SETUP Switch The INTFC SETUP (Interface Setup) switch is accessible from the rear pan
Isolated Remote Analog Interface Operation DLM 600W Series 2-2 M51A Option 2.1.1 INTFC SETUP Switch Functions The following sections describe the
DLM 600W Series Isolated Remote Analog Interface Operation Figure 2–1. Rear Panel View, Low–Voltage Models Figure 2–2. Rear Panel View, High–
Isolated Remote Analog Interface Operation DLM 600W Series 2.3 Isolated Analog Interface Connector The ISOLATED ANALOG INTERFACE connector is a 25-
DLM 600W Series Isolated Remote Analog Interface Operation M51A Option 2-5 2.3.1 ISOLATED ANALOG INTERFACE Functions The following sections descr
Isolated Remote Analog Interface Operation DLM 600W Series 2-6 M51A Option Analog Programming Signals OVP PROGRAMMING INPUT: Pin-3, an input sign
DLM 600W Series Isolated Remote Analog Interface Operation M51A Option 2-7 CURRENT RESISTANCE PROGRAMMING OUTPUT: Pin-22 provides a 1mA current sou
Isolated Remote Analog Interface Operation DLM 600W Series 2-8 M51A Option 2.4.1 Voltage Source Programming of Output Voltage Setting up for volt
DLM 600W Series Isolated Remote Analog Interface Operation M51A Option 2-9 4. Program the other parameters to the desired limit values: VOLTAGE PR
Isolated Remote Analog Interface Operation DLM 600W Series 2-10 M51A Option 2.4.6 Resistance Programming of OVP Setting up for resistance program
DLM 600W Series Isolated Remote Analog Interface Operation M51A Option 2-11 3. Connect a jumper from Pin-13 to Pin-12. 4. Connect a jumper from
Isolated Remote Analog Interface Operation DLM 600W Series 2-12 M51A Option 2.7 Remote Digital Status Signals Digital signals are available for re
About AMETEK AMETEK Programmable Power, Inc., a Division of AMETEK, Inc., is a global leader in the design and manufacture of precision, programmable
This page intentionally left blank. ii
Important Safety Instructions Before applying power to the system, verify that your product is configured properly for your particular application.
This page intentionally left blank. iv
Product Family: DLM 600W Series Power Supplies Warranty Period: Five Years WARRANTY TERMS AMETEK Programmable Power, Inc. (“AMETEK”), provides this w
This page intentionally left blank. vi
CONTENTS SECTION 1 M51A OPTION OVERVIEW 1.1 Introduction .......................
Comentarios a estos manuales