Isolated Remote Analog Interface Operation DLM 600W Series
2-8 M51A Option
2.4.1 Voltage Source Programming of Output Voltage
Setting up for voltage source programming of the output voltage is as follows:
1. Set Position-1, V, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming
range.
2. Set Position-1, V, of the INTFC SETUP switch ON (up) for 0-10VDC programming
range.
3. Connect the external programming voltage source to the ISOLATED ANALOG
INTERFACE connector, with positive to Pin-9 and negative to Pin-12.
4. Program the other parameters to the desired limit values: CURRENT PROGRAMMING
INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3, with respect to pin-12.
5. Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE
connector to Pin-15.
2.4.2 Voltage Source Programming of Output Current
Setting up for voltage source programming of the output current is as follows:
1. Set Position-2, I, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming
range.
2. Set Position-2, I, of the INTFC SETUP switch ON (up) for 0-10VDC programming range.
3. Connect the external programming voltage source to the ISOLATED ANALOG
INTERFACE connector, with positive to Pin-10 and negative to Pin-12.
4. Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING
INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3, with respect to pin-12.
5. Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE
connector to Pin-15.
2.4.3 Voltage Source Programming of OVP
Setting up for voltage source programming of OVP is as follows:
1. Set Position-3, OVP, of the INTFC SETUP switch to OFF (down) for 0-5VDC
programming range.
2. Set Position-3, OVP, of the INTFC SETUP switch ON (up) for 0-10VDC programming
range.
3. Connect the external programming voltage source to the ISOLATED ANALOG
INTERFACE connector, with positive to Pin-3 and negative to Pin-12.