M51A Option Overview DLM 600W Series
1.3 Specifications
1.3.1 Electrical Specifications
Remote Voltage Programming Accuracy, 0-5/10V Inputs:
Output Voltage: 0.5% of Vmax
Output Current: 0.75% of Imax
OVP: 1.0% of 1.1 X Vmax
Remote 4-20mA Programming Accuracy:
Output Voltage: 0.75% of Vmax
Output Current: 1.0% of Imax
1.3.2 Supplemental Characteristics
Remote Resistance Programming Accuracy, 0-5k Input:
Output Voltage: 1.0% of Vmax
Output Current: 1.5% of Imax
OVP: 1.5% of 1.1 X Vmax
Remote Monitor Accuracy:
Output Voltage, 0-5/10V ranges: 0.5% of Vmax
Output Voltage, 4-20mA: 0.75% of Vmax
Output Current, 0-5/10V ranges: 0.75% of Imax
Output Current, 4-20mA: 1.0% of Imax
1-2 M51A Option