Isolated Analog Programmer Operation DLM-E Series and DCS-E Series
2.3.12 Local/Remote Application
An external relay or switch may be used to select the Local/Remote function.
1. Connect one side of the contacts to Pin-15 (+16 VDC Auxiliary Output) on connector J4.
Connect the other contact to Pin-2. Connect the wiper to Pin-1, Analog Control Input.
2. Remote operation results when Pin-1 is low (Pin 1-2) and local supply operation results
when Pin-1 is high (Pin1-15).
13 1
Remote
Local
2
25 15
14
Figure 2–7 Using Local/Remote Operation with Contact Closure