
M51A Option Overview DLM-E Series and DCS-E Series
1-2 M51A Option
1.3 Specifications
1.3.1 Electrical Specifications
Remote Voltage Programming Accuracy, 0-5/10V Inputs:
Output Voltage: 0.5% of Vmax
Output Current: 0.75% of Imax
OVP: 1.0% of 1.1 X Vmax
Remote 4-20 mA Programming Accuracy:
Output Voltage: 1.0% of Vmax
Output Current: 1.0% of Imax
Burden voltage of 6.25 VDC (312.5 ohms nominal)
1.3.2 Supplemental Characteristics
Remote Resistance Programming Accuracy, 0-5kΩ Input:
Output Voltage: 1.0% of Vmax
Output Current: 1.5% of Imax
OVP: 1.5% of 1.1 X Vmax
Remote Monitor Accuracy:
Output Voltage, 0-5/10V ranges: 0.5% of Vmax
Output Voltage, 4-20mA: 1.0% of Vmax
Output Current, 0-5/10V ranges: 0.75% of Imax
Output Current, 4-20mA: 1.0% of Imax
Electrical Isolation:
500 VDC from all isolated inputs to supply output
Comentarios a estos manuales