Ametek DCS-E 1kW Series Programming Manual Manual de usuario Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
Isolated Analog Programmer Operation DLM-E Series and DCS-E Series
2.3.4 Resistance Programming of Output Voltage
SW1 Switch Settings
SW1-1 ON (1) = 0–5K
291213 1
25 21
14
Set up for resistance programming of the output voltage as follows:
1. Set SW1-1, V PROG, to ON (1) for 0-5VDC programming range.
2. Connect the external programming resistance, 0-5k, to the ISOLATED ANALOG
PROGRAMMER connector, J4, from Pin-9 to Pin-12.
3. Connect a jumper from Pin-21 to Pin-9 to connect the 1mA current source.
4. Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER
connector, J4, to Pin-2 to enable remote control.
5. Program the other parameters to the desired limit values.
2-10 M51A Option
Vista de pagina 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 31 32

Comentarios a estos manuales

Sin comentarios