Ametek DCS-E 1kW Series Programming Manual Manual de usuario Pagina 27

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 26
DLM-E Series and DCS-E Series Isolated Analog Programmer Operation
2.3.9 Programming the Shutdown Function
2
13
1
25
15
+5V
GND
14
Figure 2–3. Using Shutdown with a DC Input (Positive Logic)
2.3.10 TTL Shutdown
Set up for Shutdown input signal as follows:
1. Connect the shutdown signal source to the ISOLATED ANALOG PROGRAMMER
connector, J4, with positive to Pin-14 and the return to Pin-2.
2. Set switch SW1-6 to select the desired logic as defined in the following table.
Switch SW1-6 Setting Signal Level Output Condition
Low OFF
OFF (0) = Negative Logic
High ON
High OFF
ON (1) = Positive Logic
Low ON
M51A Option 2-15