Avionics Software 193
8.2 –AMD Power Groups
The –AMD option supports both AC and DC modes of operation. The correct mode is a function of
the EUT to be tested and the operator must select the corresponding operating mode first. This can
be done from the front panel if needed or using the Gui program. Use of the Gui program for all
settings will be assumed for the remainder of this chapter.
Five power groups are covered in the Airbus A400M AMD-24 directive:
Single Phase 115VAC / Variable Frequency, 390 – 620 Hz.
Three Phase 115VAC / Variable Frequency, 390 – 620Hz.
Single Phase 115VAC / 400 Hz
Three Phase 115VAC / 400 Hz
The required steady state output settings for each power group must be selected based on the type of EUT to
be tested. These settings can be made from the front panel of the power source or from the main Gui control
screen.