Ametek Compact i/iX Series Software Manual Manual de usuario Pagina 175

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 203
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 174
User Manual - Rev H California Instruments
Avionics Software 175
#
Test
No.
Subject
Test Limits
DO160 Ref.
Comments
Test File
33
6
Cf Figure 1.1 - N = 1 to 22
Table 1.4
n./a
D6P0_APP1TransT14_N1
34
7
Square wave DC load variations
Fig 7-A and 7-B
n/a
Apply Fig 7-A or 7-B depending on
distribution bus bar
35
7.1
Square wave DC load variations
Figure 7-A
n/a
A380 Version
D7P0_DCFIG7A_A380
36
7.1
Square wave DC load variations
n/a
Other Airbus
D7P0_DCFIG7A_AIRB
37
7.2
Square wave DC load variations
Figure 7-B
n/a
A380 Version
D7P0_DCFIG7B_A380
38
7.2
Square wave DC load variations
Figure 7-B
n/a
Other Airbus
D7P0_DCFIG7B_AIRB
39
8
Ripple Voltage
Fig 8
16.6.1.2
Requires additional equipment
7.4.1.5 Table E:
#
Test
No.
Subject
Test Limits
DO160 Ref.
Comments
Test File
1
2
1.1
Maximum Voltage - Norm and Emer
32V DC
16.6.1.1.b (1)
E1P0_NORM_MAXV
3
1.2
24V DC
16.6.1.1.b (2)
E1P0_NORM_MINV
4
1.3
Minimum voltage - Emergency
operation
18.5V DC
16.6.1.1.b (3)
E1P0_EMER_MINV
5
2
Voltage Surge - Figure 13
6
2.1
Normal Transients
36V for 100ms
16.6.1.4.b
Use specified limit iso DO160
E2P0_NORMVSURGE1
7
2.2
Normal Transients
35V for 200ms
16.6.1.4.b
Use specified limit iso DO160
E2P0_NORMVSURGE2
8
2.3
Normal Transients
34V for 300ms
16.6.1.4.b
Use specified limit iso DO160
E2P0_NORMVSURGE3
9
2.4
Normal Transients
18.5V for 5 secs
16.6.1.4.b
Use specified limit iso DO160
E2P0_NORMVSURGE4
10
3
Voltage Surge - Figure 13
11
3.1
Abnormal Transients
36V for 1 sec
16.6.2.4.c
Apply also Appendix 3 test
E3P0_ABNVSURGE1
12
3.2
Abnormal Transients
33V for 3 sec
16.6.2.4.c
Apply also Appendix 3 test
E3P0_ABNVSURGE2
13
3.3
Abnormal Transients
0V for 5 secs
16.6.2.3.b
Apply also Appendix 3 test
E3P0_ABNVSURGE3
14
3.4
Abnormal Transients
Disconnects for 5
secs
n/a
Appendix 3 tests for multiple power
input equipment.
E3P3_APPENDIX3
15
4
Voltage Spikes - Fig 3-C
Peak voltage 600V
17.4
Requires additional equipment
16
5
Switching Transients
Appendix 1
n./a
Appendix 1 DC Switching Transients
17
5.1
Cf Figure A
Table 1.2 - T1 >= 3
msec
n./a
E5P0_APP1TransientsA
18
5.2.1
Cf Figure B
Table 1.2 - N=1
n./a
E5P0_APP1TransientsB_N
1
19
5.2.2
Cf Figure B
Table 1.2 - N=2
n./a
E5P0_APP1TransientsB_N
2