User Manual Rev H California Instruments
162 Avionics Software
7.2 ABD Power Groups
The ABD option supports both AC and DC modes of operation. The correct mode is a function of the
EUT to be tested and the operator must select the corresponding operating mode first. This can be
done from the front panel if needed or using the Gui program. Use of the Gui program for all settings
will be assumed for the remainder of this chapter.
Five power groups are covered in the ABD0100.1.8 directive:
Group
Description
A
115VAC / 400 Hz (CF)
B
26 VAC / 400 Hz
C
115VAC / Variable Frequency (VF), 360 800 Hz.
D
28VDC, Conventional DC network.
E
28VDC, No Break Power Transfer (NBPT) DC network.
The required steady state output settings for each power group must be selected based on the type of EUT to
be tested. These settings can be made from the front panel of the power source or from the main Gui control
screen