Ethernet Configuration and Remote Programming SG Series Programming
5-26
M550129-03 Rev K
5.5.5
POWER
The Power page (only in SGI) displays updated information for the following
parameters:
Figure 5-17. SGI Power Page (not in SGA)
Volts: value above is updated with actual voltage output of the power
supply
Current: value above is updated with actual live current output of the
power supply
Power (kW): value above is updated with actual power output of the
power supply
Max Volts: the programmed voltage setting limit
Max Current: the programmed current setting limit
Max Watts: the programmed power setting limit
EXECUTE/UPDATE: puts into effect the newly programmed limits
Stop Volts: the programmed voltage setting when you exit power mode