Ametek SFA Series Ethernet Programming Manual de usuario Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 159
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
IEEE/GPIB Features, Functions, Specifications SG Series Programming
2-2
M550129-03 Rev
K
2.4
READBACK FUNCTIONS
Actual measured voltage and current
Voltage and current settings
Soft voltage and current limits
Overvoltage protection setting
Status and Accumulated Status registers
Programming error codes
Fault codes
Manufacturer, power supply model, and firmware version identification
2.5
SPECIFICATIONS
Specifications are subject to change without notice. Refer to your SGA or SGI
power supply operation manual for effects of line regulation, load regulation,
and temperature on accuracy specifications.
2.5.1
Programming Resolution
Voltage: 0.002% of full scale
Current: 0.002% of full scale
Overvoltage Protection: 0.002% of full scale (full scale is 110% of max
output voltage.)
2.5.2
Programming Accuracy
Voltage: ± ( 0.1% of maximum output voltage)
Current: ± ( 0.4% of maximum output current)*
Overvoltage Protection: ± (1.0% of max output voltage)
* After 30 minutes operation with fixed line, load, and temperature.
2.5.3
Readback Resolution
Voltage: ± 0.002% of full scale
Current: ± 0.002% of full scale
2.5.4
Readback Accuracy
Voltage: ± ( 0.15% of full scale output voltage)
Current: ± ( 0.4% of full scale output current)*
* After 30 minutes operation with fixed line, load, and temperature.
Vista de pagina 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 158 159

Comentarios a estos manuales

Sin comentarios