Vista de pagina 78
Programming Manual Lx \ Ls Series II
75
FREQuency:TRIGgered
This command programs the frequency that the output will be set to during a triggered step or
pulse transient.
Command Syntax [SOURce:]FREQuency:TRIGgered<NRf+>
Parameters Refer to specifications table in User Manual
Unit HZ (Hertz)
*RST Value 60 Hz
Example FREQ:TRIG 50
Query Syntax [SOURce:]FREQuency:TRIGgered?
Returned Parameters <NR3>
Related Commands FREQ FREQ:MODE