Programming Manual Lx \ Ls Series II
171
HEADER
EXTENSION
ARGUMENT
DEFINITION
GPIB GET message.
VAL
From parameter
minimum to
maximum value
Final ramp or step value in volts, hertz,
amps, degrees, sine wave or square wave.
WVF
A, B, C
SNW, SQW
Waveform
OPN
Open output relays
CLS
Close output relays
VLT
A, B, C
Used with TLK to request measurement of
the output voltage
ELT
Used with TLK to request total
accumulated run time.
CUR
A, B, C
Used with TLK to request measurement of
the output load current.
PWR
A, B, C
Used with TLK to request measurement of
the real output power.
APW
A, B, C
Used with TLK to request measurement of
the apparent output power.
PWF
A, B, C
Used with TLK to request measurement of
the output power factor.
PZM
A, B, C
Used with TLK to request measurement of
the output phase angle.
FQM
Used with TLK to request measurement of
the output frequency.
Table 8-3: APE language syntax program headers