Ametek Lx Series II Programming Manual Manual de usuario Pagina 217

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 242
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 216
Programming Manual Lx \ Ls Series II
213
MS704:ABNormal:VOLTage:TRANsient:OVER
This command will run the abnormal over voltage transients test.
Command Syntax MS704:ABNormal:VOLTage:TRANsient:OVER
Parameters none
Examples MS704:ABN:VOLT:TRAN:OVER
Query Syntax none
MS704:ABNormal:VOLTage:TRANsient:UNDer
This command will run the abnormal under voltage transients test.
Command Syntax MS704:NORMal:VOLTage:TRANsient:UNDer
Parameters none
Examples MS704:NORM:VOLT:TRAN:UND
Query Syntax none
MS704:ABNormal:VOLTage:TRANsient:COMBination
This command will run the abnormal combination voltage transients test.
Command Syntax MS704:ABNormal:VOLTage:TRANsient:COMBination
Parameters none
Examples MS704:ABN:VOLT:TRAN:COMB
Query Syntax none
MS704:ABNormal:FREQuency:TRANsient[:ALL]
This command will run all the abnormal frequency transients tests.
Command Syntax MS704:ABNormal:FREQuency:TRANsient[:ALL]
Parameters none
Examples MS704:ABN:FREQ:TRAN
Query Syntax none
MS704:ABNormal:FREQuency:TRANsient:OVER
This command will run the abnormal over frequency transients test.
Command Syntax MS704:ABNormal:FREQuency:TRANsient:OVER
Parameters none
Examples MS704:ABN:FREQ:TRAN:OVER
Query Syntax none
Vista de pagina 216
1 2 ... 212 213 214 215 216 217 218 219 220 221 222 ... 241 242

Comentarios a estos manuales

Sin comentarios