Chapter 2: Installation
Installation and Maintenance Manual
4
2.2: Electrical Installation
The Micro-Set is designed for use in an industrial environment and incorporates extensive transient
suppression circuitry. However, the same general installation rules should be followed that are used on
all microprocessor-based equipment. Incoming AC lines should be from a clean power source and
lines carrying computer level signals should not be routed in the same conduit as high voltage, transient-
producing circuits such as variable speed drives, welders or DC switching circuits.
The 1995L PLS is designed to be used with a Gemco 0 to 10 Volt Analog LDT. Wiring for this system
is shown in Fig. 10-1, Fig. 10-2 and Fig. 10-3; Chapter 10: Wiring Diagrams. This wiring diagram is
applicable for all standard 1995 PLSs.
2.3: Wiring Instructions
Attach the pre-wired plug on the LDT cable to the LDT and route the shielded cable through a separate
grounded (earth ground) metal conduit to the panel and connect the mating half terminal block to the
1995L PLS. Be sure the shield wire is connected to Pin 1 of the 16-place connector.
When extension to the factory supplied cable is necessary, a junction box should be used to connect the
wire leads and the cable shields from one cable to the other. The cable shield should be grounded at the
1995 Micro-Set only.
AC line voltage - 115V AC 60Hz - should be connected to the 1995L PLS at the AC power