Chapter 3: Programming
Installation and Maintenance Manual
12
Programming Reset-to-Preset Value
The Reset-to-Preset Value is programmed by entering the following:
A) Unit must be in the Program mode.
B) The Reset-to-Preset must first be enabled before you can store any values. To accomplish this,
depress . A zero (0) disables a
ENT
CIR#
-
1
-
6 6
--
(0 or 1)
-
ENT
-
function and a one (1) enables it.
C) Once the Reset-to-Preset has been enabled, you can store a value in memory. This is accom-
plished by depressing
ENT
CIR#
-
1
-
6 0
--
(Desired Reset Value)
-
ENT
-
NOTE: Valid numbers for CIR# 160 are zero (0) through the programmed scale factor, less one (1).
.
3.14: Motion Detector
A programmable Motion Detect output will energize a relay when the transducer speed exceeds the
customers preprogrammed RPM value.
The motion detector is set by entering the following:
A) Unit must be in the Program mode.
B) The motion detect must first be enabled before you can store any values. To accomplish this,
depress . A one (1) will enable the motion
ENT
CIR#
-
5
-
5
-
(0 or 1)
-
ENT
-
detect output circuit, and LS6 will now be your motion detect output relay. If a zero (0) is
entered, the motion detect feature is disabled and LS6 will function as a normal limit switch.
C) To set the value at which the motion detect relay energizes, depress
ENT
CIR#
-
1
-
7 6
--
(RPM Value)
-
ENT
-
NOTE: A CIR #176 can only be entered if the motion detect option is enabled.
.