Features, Functions, and Specifications Sorensen SF Series
1-2 M550292-03 (Programming)
Readback Functions
Actual measured voltage and current
Current settings
Soft current limit
Status and Accumulated Status registers
Programming error codes
Fault codes
Manufacturer, power supply model, and firmware version identification
1.3 Specifications
Programming Resolution
Current: 0.002% of full scale
Programming Accuracy
Current: ± ( 0.4% of maximum output current)*
Readback Resolution
Voltage: ± 0.002% of full scale
Current: ± 0.002% of full scale
Readback Accuracy
Voltage: ± ( 0.15% of full scale output voltage)
Current: ± ( 0.4% of full scale output current)*
* After 30 minutes operation with fixed line, load, and temperature.
Note: Refer to the SFA or SFI power supply Operation manual for effects of line regulation,
load regulation, and temperature on accuracy specifications.
Specifications subject to change without notice.