Sorensen SF Series IEEE 488.2 and SCPI Command Operation
3.10
3.10.1
3.10.2
TRIGGER SCPI Command Subsystem
TRIGGER SCPI Command Summary
TRIGger
:ABORt
:RAMP
:TYPE <1|2|3>
TRIGGER SCPI Command Reference
Command Description SCPI
TRIGger
Trigger subsystem. C
:ABORt
Clears all settings of voltage and current
upon trigger.
N
:RAMP
Implements current ramping function
previously programmed by the
SOURce:CURRent:RAMP commands.
N
:TYPe<1|2|3>
Implements current values previously
programmed by the
SOURce:CURRent:LEVel:TRIGger
commands.
Valid arguments are 1 (Not Used),
2 (Current), or 3 (Both).
N
3.11 CALIBRATION SCPI Command Subsystem
See Section 4 for calibration procedures.
WARNING
Please refer to the power supply manual for further information before performing
calibration procedures. Calibration must be performed by qualified personnel who
appropriately deal with attendant hazards. If calibration is not performed properly,
functional problems could arise, requiring that the supply be returned to the factory.
M550292-03 (Programming) 3-19